Grindinės TG/ICH tipo klimatinės kameros
Constructional features
• High quality 304 stainless steel exterior and interior.
• Casters for easy mobility when installing or moving environmental test chamber.
• Convenient maintenance.
- Available to check total operating time.
• Unique door lock & trim.
• Vice lock type door catch and foamed silicone packing ensure perfect chamber seal.
• Cable port for external probes or wires.
• 50mm diameter cable port comes standard on the left side of the unit.
Additional 50mm or 80mm diameter cable ports can be custom ordered.(optional)
• Container type tank for easy adding and changing of water.
Maintenance of the water tank can be easily performed from the front side.
• Door locker.(optional)
• Cyclic defrost functions does not affect the temperature & humidity control for extended operation.
(under 15? set value)
• Powerful 2 sirocco fans maintain constant air flow rate in the chamber.
Additional TH-ICH 300,800 Features
• In the event of a validation the apparatus correctly controls eachlight and then transfers accurate data in
and is equipped with light sensors. (UV light sensor/VIS light sensor)
• Samples that have to be exposed to the light in which it is completely near UV energy of less than
200w-hr/? is provided to compare directly the results from overall intensity of less than 1.20 million lux-hr,
drug substances and reagents.
• Total fluorescent lamp & UV lamp indicator and operating time indicator.
• The safety switch protects user by automatically lamp off during door open.
Relative humidity - Temperature ranges
Control operation
• Microprocess PID control/Auto-tuning/Calibraton.
• Digital LCD display with touch-sensitive 7 keypads.
• Easy operation with wide LCD screen.
Temperature & humidity/ timer settings and operating condition.
• Program patterns are memorized for 10 years due to a battery built into the PCB.
• Expansionary parameters inputting. (Conveniently display by letters)
• Programming operation.
• Computer interface.
Save data in the Excel format.
Software provided.
Storage of program information, backup of value settings / recovery, and temperature / humidity values.
RS-232C as standard offer.
• Recorder. (Optional)
6-point dot type recorder with digital display.
Digital recorder. (6-Channels)
Safety functions
• Leakage breaker for power supply.
• Over current protector.
• Overheat protector.
• Switch-off after alarm for over heating.
• Door open warning alarm.
• Water empty.
• Alarming when complete Photostability Test. (Only TH-ICH series)
Accessories and options
Viewing Window A observation window is installed ONLY on all floor type chambers. (TH/ TC series and TH-CR-270) A tempered dual windows provided a clear view of your specimen during testing. Improved lighting provided. |
|
Inner door A inner glass door is provided inside the chamber door so that specimens can be observed. Applicable to some of floor type chambers. (TH-G, I-180, 300, 408L/ TC-180, 300, 408L and TH-CR-270 ONLY) All of the tabletop chambers are provided one inner glass door. |
|
Temperature and Humidity recorder (digital) Recording range: -60 to 150?/ 0 to 100% RH |
|
Access Port A through hole of 50 or 80mm dia. (2.0 or 3.2" dia.) is provided on the wall of chamber to allow electrical cables to be introduced into the chamber. A 50mm hole is provided, maximum two holes (50 or 80mm) are optional.Equipped with rubber plug. Standard 50mm hole is on the left side. |
|
Water Supply Water supply system to supply pure water for humidification.Cartridge type water tank for easy water supply Maintenance can be done easily from the front side A center window allow to check the amount of water remaining easily |
|
Shelf Wire and perforated type shelves (included shelf brackets) are made of durable stainless steel. Standard specification shelves and shelf brackets are added as required. |
|
Warning Signal Light A signal light to light up when malfunction occurs. Can be located upper plate of unit. |
Floor type chambers (TH-G / TH-I / TH-TG / TH-ICH series)
Cat. No. | Description | Models | |||
TH-G | TH-I | TH-TG | TH-ICH | ||
AAA8T500
|
Recorder (6 points) | ? | ? | ? | ? |
AAA8T505
|
Recorder (Digital, 6 channels) | ? | ? | ? | ? |
AAA8T541
|
Interface converter included a cable (5m / 16.4ft) | ? | ? | ? | ? |
AAA8T542
|
Interface cable (5m / 16.4ft) | ? | ? | ? | ? |
AAA80550
|
Warning signal lamp | ? | ? | ? | ? |
AAA81552
|
Inner glass door (only for 180L chambers) | ? | ? | - | - |
AAA81551
|
Inner glass door (only for 270, 300, 408L chambers) | ? | ? | - | - |
EDA8212
|
Wire shelf for TH-G-180 / TH-I-180 / TC-G-180 * | ? | ? | - | - |
EDA8213
|
Wire shelf for TH-G-300 / TH-I-300 / TC-G-300 * | ? | ? | - | - |
EDA8214
|
Wire shelf for TH-G-408 / TH-I-408 / TC-G-408 * | ? | ? | - | - |
EDA8215
|
Wire shelf for TH-G-800 / TH-I-800 / TC-G-800 * | ? | - | - | - |
EDA8216
|
Wire shelf for TH-G-1000 / TH-I-1000 / TC-G-1000 * | ? | - | - | - |
RTD1195
|
Wire shelf for TH-TG-180 | - | - | ? | - |
RTD1196
|
Wire shelf for TH-TG / ICH-300 | - | - | ? | ? |
RTD1197
|
Wire shelf for TH-TG-408 | - | - | ? | - |
RTD1198
|
Wire shelf for TH-TG / ICH-800 | - | - | ? | ? |
RTD1199
|
Wire shelf for TH-TG-1000 | - | - | ? | - |
STT1040
|
Wire shelf for TH-CR-270 * | - | - | - | - |
AAA80602-1
|
Perforated shelf for TH-G-180 / TH-I-180 / TC-G-180 * | ? | ? | - | - |
AAA80602-2
|
Perforated shelf for TH-G-300 / TH-I-300 / TC-G-300 * | ? | ? | - | - |
AAA80602-3
|
Perforated shelf for TH-G-408 / TH-I-408 / TC-G-408 * | ? | ? | - | - |
AAA80602-4
|
Perforated shelf for TH-G-800 / TH-I-800 / TC-G-800 * | ? | - | - | - |
AAA80602-5
|
Perforated shelf for TH-G-1000 / TH-I-1000 /TC-G-1000 * | ? | - | - | - |
AAA80604-1
|
Perforated shelf for TH-TG-180 | - | - | ? | - |
AAA80604-2
|
Perforated shelf for TH-TG / ICH-300 | - | - | ? | ? |
AAA80604-3
|
Perforated shelf for TH-TG-408 | - | - | ? | - |
AAA80604-4
|
Perforated shelf for TH-TGTG / ICH-800 | - | - | ? | ? |
AAA80604-5
|
Perforated shelf for TH-TG-1000 | - | - | ? | - |
AAA80630-1
|
Perforated shelf for TH-CR-270 * | - | - | - | - |
AAA8T610
|
Cable port (Ø 50mm / 2.0" | ? | ? | ? | ? |
AAA8T611
|
Cable port (Ø 80mm / 3.2") | ? | ? | ? | ? |
AAA8T621
|
Water purifier | ? | ? | ? | ? |
AAA80622
|
Water cartridge tank | ? | ? | ? | ? |
RTD0794
|
Humidity sensor | ? | ? | ? | ? |
CFA1910
|
Temperature sensor (RTD type) | ? | ? | ? | ? |
RTD1190
|
Fluorescent Lamp(Cool White) for TH-ICH-300 | - | - | - | ? |
RTD1191
|
Fluorescent Lamp(Cool White) for TH-ICH-800 | - | - | - | ? |
RTD1188
|
UVA Lamp for TH-ICH-300 | - | - | - | ? |
RTD1189
|
UVA Lamp for TH-ICH-800 | - | - | - | ? |
AAA80680
|
THE-680 UV Sensor TH-ICH | - | - | - | ? |
AAA80681
|
THE-681 Illumination Sensor for TH-ICH | - | - | - | ? |
EDA9175
|
ULPA filter (optional) | - | - | - | - |
EDA9184
|
HEPA filter (1EA included) | - | - | - | - |
AAA80661
|
Door lock device | - | - |